Technical Specifications
| Parameter | Specification |
|---|---|
| Temperature Range | -40 to +150 deg C |
| Mechanical Load | Up to 500kN simultaneous |
| Thermal Ramp Rate | 0.5-5 deg C/min |
| Cycle Count | Programmable up to 9999 |
Key Features
- Simultaneous mechanical load and temperature cycling
- Walk-in type environmental chamber
- Programmable multi-step test profiles
- Automatic test termination on specimen failure
Why Combined Testing Matters
Composite insulators experience simultaneous mechanical and thermal stresses in service. IEC 61109 requires combined tests to verify integrity under realistic conditions. Single-parameter tests miss interaction effects.
Looking for This Equipment?
Contact Contune International for detailed quotations, delivery timelines, and technical support on insulator test and production machinery.
Request a Quote →